Square Carbon Cup for CE-Meter (Carbon and Silicon Analyzer)

The square expendable carbon cup is for determining the Carbon equivalent, % Carbon and % Silicon in molten iron by using the  principle of thermal analysis.
Add to Inquiry
Description

Application:
The square expendable carbon cup is for determining the Carbon equivalent, % Carbon and % Silicon in molten iron by using the  principle of thermal analysis.

Feastures:
• International standard specification.
• Japan-imported couple wire. 
• High accuracy, rapid reaction, reliability, stability, smooth cooling curve and good reproductivity. 
• Sold to Japan, Korea, Thailand, Malaysia, Taiwan etc. 

Determination of thermal stability of sample cup And Instrument Adjustment
One: option of instrument and electric furnace
Be sure to select the specific carbon silicon analyzer and hot metal within the specified test furnace. the replacement of components when the next test furnace hot metal will be change.

Two: data testing methods
Example: Thermal analysis of the test sample cup should be 3 to 5 consecutive (arrange it according the time), e.g. the test result of Si% is 1.80%, 1.82%, 1.86%, 1.88%, 1.90%. Testing is completed record data.

Three: analysis
Stability. According above testing result, the highest one is 1.80%, lowest one is 1.70%, fluctuation gap is 0.1, average value is 1.75% (±0.05).
Instrument adjustment.
If the chemical analysis of Si% molten iron content was 1.85% when the original apparatus should be set based on the si values of 0.1 and then raised to complete the adjustment (if the former setting of Si is -0,2, should change at -0.1). when test again, the content of Si% will become 1.85%, the adjustment is over, can work now.

Four: attention
1)the hot metal temperature in the sample cup should not exceed 1350 ℃.
2)Optimum temperature of ductile iron is 1200 ℃ ~ 1250 ℃.
3)Optimum temperature of Gray Iron 250, 300 is 1250 ℃ ~ 1350 ℃
4)The abnormal situation like low carbon high silicon hot metal composition will cause instruments to measure the normal C% and Si% no data.

Relevant
Carbon Equivalent Meter Cup (Thermal Analysis Cup) for Casting Industry Analysis
•International standard specification.
•Japan-imported couple wire.
•High accuracy, rapid reaction, reliability, stability, smooth cooling curve and good reproductivity.
•Sold to Japan, Korea, Thailand, Malaysia, Taiwan etc.
SPG-cup for Stove-front Molten Iron Quality Management Meter
same like carbon cup, but without tellurium coating inside. test the molten iron nodularity (rate of spheroidization) for stove-front molten iron quality management meter.
Carbon Cup Holder (Front Part) to Connect cup and CE-Meter
Carbon Cup Holder (front part) is the connector between carbon cup and CE-Meter, is CE-Meter accessory.
Carbon Cup Holder (Full Part) to Connect Carbon Cup and Carbon Analyzer
the holder of carbon cup, connect carbon cup and CE-Meter.
Review


ver_code
1/3
X