Hot Sell Thermal Analysis Expendable/Disposable Thermocouple Types R, S, K etc. Used in Steel Mills

Views : 837
Update time : 2016-10-10 15:33:50

Hot Sell Thermal Analysis Expendable/Disposable Thermocouple Types R, S, K etc. Used in Steel Mills :
1. Purpose and Working Principle of Thermal Analysis Disposable Thermocouple:
Used as a accessory product for temperature gun for measuring the temperature of molten steel and high-temperature molten metal, thermal analysis disposable thermocouple is disposable. Based on the thermoelectric effect of metals, molten metal's high temperature effecting on the connect of the two different material wire, the other two side will have a electromotive force.
2.  Product Specifications and Performance Comparisons:


Name

Model

Type

Permissible Deviation

Recommended Temperature

Max Temperature

Response Time

Platinum-30% Rhodium/Platinum-6% Rhodium thermocouple

KB-602/604

B

±5ºC/±3ºC

1500-1700ºC

1800ºC

4~6s

Platinum-10% Rhodium/Platinum thermocouple

KS-602/604

S

±5ºC/±3ºC

1500-1700ºC

1800ºC

4~6s

Platinum-13% Rhodium/Platinum thermocouple

KR-602/604

R

±5ºC/±3ºC

1500-1700ºC

1800ºC

4~6s

Tungsten 30%/ tungsten-rhenium 25%

KW-602

W

±5ºC/±3ºC

1500-1700ºC

1800ºC

4~6s


3.  Structure
Disposable thermocouple is mainly composed of thermal analysis temperature measuring probe and a big paper tube. Positive wire and negative wire of the temperature measuring probe are welded to a compensating lead wire embedded in a support bracket covered by a small paper tube. The thermo wires are supported and protected by quartz. The temperature measuring probe is covered by a cap to protect from dregs. All the components are put into a thermocouple tip and are bonded by fire-resistant filler into a whole. Therefore, the fast thermocouple is for one-time use.
4.  Usage
-- To select the appropriate length of protective paper tube and temperature measuring gun according to the object and scope of the measurement
-- Attach the disposable thermocouple to the temperature measuring gun, make the pointer of the secondary instrument (or digital display) back to zero. Begin to measure. 
-- It is recommended to insert the disposable thermocouple in to the molten steel at the depth of 300-400mm. Do not touch the furnace wall or scum. Bring up the temperature measuring lance immediately after the secondary instrument get results. The soak time of disposable thermocouple in molten steel should less than 5 seconds, otherwise the gun may be burned out.
-- Change the used thermocouple into a new one, and pause for a few minutes to get ready for the next measurement.